Centrifugal Pump & Circuit Hardware CIP Heater

Hot caustic for impellers, seals, seats and manifolds

Contact us

Circuit hardware

A CIP heater for pumps, valves and manifolds

The hardware of a process line, the centrifugal pumps, the mix-proof and single-seat valves, the clusters, the flow plates and manifolds, is never cleaned on its own circuit. It is cleaned by whichever circuit passes through it, and it is the part of that circuit most likely to fail a swab. A centrifugal pump has an impeller with a back shroud, a casing drain boss, a seal flush cavity and an O-ring groove at the backplate. A mix-proof valve has two seats, a leakage chamber and a balancer. Each is a crevice where wash solution moves slowly, cools, and leaves whatever it was carrying. The spray device in the tank upstream has nothing to do with it; the hardware is cleaned by temperature, chemistry and time, in that order.

That is why plants with a lot of valve hardware run the circuit hotter and longer than the tank alone would need, and why the CIP heater is sized for the circuit flow and the heat the hardware and piping lose, not for the vessel. A process-line circuit through pumps and clusters runs 70–120 gpm in 3-inch or 4-inch piping. The caustic is 1.5% at 160°F, the acid is 1% phosphoric or nitric at 130°F, and the circuit also has to be hot at its coldest point, normally a valve body on a leg that only sees flow when the cluster cycles.

The circuit is only as clean as its coldest valve body

A 120 gpm hardware circuit lifted from 60 to 165°F is a 105°F rise, about 6.3 MBtu/h on a once-through heater. Set the outlet 5°F above the 160°F caustic target and the last valve seat on the loop sees the temperature the program promised.

What the hardware circuit needs

Caustic at 1.5% and 160°F for 30 minutes is the usual program on a pump-and-valve circuit; pushing above 175°F buys little and shortens the life of the plant's own EPDM valve seats and pump O-rings, so the target is held near 160°F and the time is extended instead. The acid step runs at 130°F with 1% phosphoric or nitric, and on a hardware circuit it matters more than on a tank because mineral scale in a seal cavity or under a seat lip is where the swab fails.

Velocity is 5 ft/s in the line, 70 gpm in 3-inch or 120 gpm in 4-inch, and the pump that drives it is the CIP supply pump, with the process pumps turning but not pushing. The circuit loses heat through every uninsulated valve body and pump casing, and a long cluster with 30 valves on it can drop the solution 5°F between the supply header and the return. The heater outlet is set to cover that drop, and the return temperature is what the sanitation record should carry.

The heater we size for it

A U-tube shell-and-tube with steam in the tubes and solution in a 316L shell, either on the CIP tank recirculation loop or once-through on the supply line, depending on how the plant runs the set. Once-through on a 120 gpm circuit from 60 to 165°F, a 105°F rise, is about 6.3 MBtu/h and condenses roughly 6,500 lb/h of 15 psig steam; on a 125 psig header, condensing at 353°F, the same duty takes a markedly shorter bundle. On a tank loop the duty is set by the tank warm-up instead.

That pressure drop is the figure a hardware circuit cares about. The CIP supply pump has to push through the heater, the clusters and the return, and we hold the shell side to a few psi at circuit flow so the pump curve is not eaten by the exchanger. Shell rated 150 psig at 250°F, steam side 150 psig at 400°F, EPDM head gasket for caustic and phosphoric, FKM where the plant runs nitric hot. The bundle pulls for the carbonate and protein that a hardware circuit returns to the heater.

For a pump and valve circuit heater

Send the circuit, not the equipment list. The flow, the loss and the coldest point are what size the heater.

  • Circuit gpm and the pipe size it runs in
  • Tank recirculation or once-through supply
  • Caustic and acid set points, and which acid
  • Steam pressure at the heater inlet
  • Allowable shell-side pressure drop at circuit flow
  • Approximate heat loss, or the length and insulation of the circuit

Call and talk it through with an engineer: 1-805-484-2992

Questions about hardware circuits

Possibly, but check the return temperature first. If the supply reads 160°F and the return reads 150°F, the hardware at the far end never saw the program temperature, and the fix is heater margin: raise the outlet set point and confirm the surface supports it at circuit flow. If supply and return both read 160°F, the problem is valve pulsing or time, and the heater is doing its share.

Because a hardware circuit has nothing else to spare. The CIP supply pump has to drive 120 gpm through the heater, a run of 4-inch pipe, a cluster of valves with their own losses, the process pumps' casings and the return. A heater that takes 15 psi of that at circuit flow can push the pump off its curve and drop the velocity below 5 ft/s in the cluster. We hold the shell-side drop low by design.

The 316L shell and bundle do not care at 1% and 130°F. The head gasket does: EPDM is fine on phosphoric, but hot or frequent nitric calls for an FKM gasket, and we fit it when the program says nitric. The plant's own valve seats are a separate question for its valve supplier; many plants choose phosphoric for exactly that reason and keep EPDM everywhere.

Longer then the tank circuit it shares a program with. A plain tank is clean after 20 minutes of caustic at 160°F; a circuit with pumps and clusters usually runs 30–45 minutes so the seats and seal cavities see enough hot contact while the valves pulse. The heater does not set that time, but it does have to hold the outlet steady through all of it.

Related

Dairy Plant CIP Heaters

Applications

Dairy

Dairy circuits run the hottest caustic on this site and foul the heater itself. Why dairies pull bundles, and how pasteurizer, vat and silo loops differ.

+ Learn More
Brewery and Beverage CIP Heaters

Applications

Brewery & Beverage

Breweries heat caustic against cold vessels and carbonate scale; beverage lines run the rinse heater hardest. Circuits, temperatures and the heater for each.

+ Learn More
Food Plant CIP Heaters

Applications

Food Plants

Food soils are the heaviest we heat against: hotter, stronger caustic, bigger tanks and a chloride check for brine plants. How the heater is sized for each.

+ Learn More