Bottled water
Most CIP heaters on this site are asked to get hotter. The filtration circuit in a bottled water plant is the exception. The soil is thin: a biofilm on the wetted surfaces of cartridge and bag housings, a carbonate haze where mineral-rich source water sat in a dead leg, and whatever the sanitizer left behind. What limits the wash is the equipment. Reverse osmosis and nanofiltration elements are commonly rated to about 113°F, polypropylene cartridge housings not much higher, and a caustic circuit that overshoots by 20°F on a cold morning can shorten the life of every element in the train.
So the circuit runs warm, not hot: sodium hydroxide at 0.5–1% around 95–110°F for the biofilm, a phosphoric or citric acid step at 0.5% and roughly the same temperature for the carbonate, then a long flush with product-quality water. The heater that serves it is small in duty and large in control. A 2-inch loop carries about 30 gpm, and lifting that from a 65°F feed to 110°F is only 45°F of rise, about 675,000 Btu/h.
The fill header and bottle rinser downstream of the filters are a different circuit and can take the usual 160°F caustic. Keep the two loops separate, or the membranes see whatever the filler wanted.
Low duty and a tight ceiling call for a heater with modest surface and a steam valve that can turn down. An oversized bundle, even on 15 psig steam, will carry the loop past the membrane limit before the valve closes.
The soil on a filtration train is biological and mineral, never fat or protein, so the chemistry stays light. A 0.5–1% caustic wash at 95–110°F for 20–30 minutes lifts the biofilm. Acid at pH 2 handles the carbonate, and because the elements see it, phosphoric or citric is chosen over nitric. Flow follows the housing manufacturer's permeate and concentrate limits, which usually lands the loop in the 20–40 gpm range on a 2-inch header.
The flush matters as much as the wash. Residual caustic in a membrane housing shows up as a pH excursion on the product side, so plants rinse with treated water until conductivity returns to baseline. That water is often warmed to 90–100°F to speed the rinse, which is a second small heating duty on the same heater or on a plate exchanger beside it.
At 110°F and modest pressure this is one of the few CIP duties where a gasketed plate pack on hot water is a good fit. A 316L plate pack with EPDM gaskets, fed from the plant's hot-water loop rather than from steam, gives a close approach and almost no overshoot, and the plates come out if a biofilm takes hold. Where only steam is available, a compact U-tube shell-and-tube with steam in the tubes and solution in the shell does the job, but we size it for the 675,000 Btu/h it needs and not a round number above it.
Either way the steam or hot-water valve needs a temperature sensor at the heater outlet, a high-limit trip set a few degrees under the element rating, and a bypass so the loop keeps moving if the heater is isolated. We supply the exchanger and tell you the surface and approach so the controls engineer can set those limits with margin.
The membrane and housing ratings decide this heater more than the chemistry does, so lead with them. Send the following and we will return a construction and surface area, or a plate count and frame size, with the controls margin noted.
Call and talk it through with an engineer: 1-805-484-2992
Because the elements will not survive it. Thin-film membranes loose rejection above their rated temperature, and housing seals and cartridge end caps follow soon after. A plant that ties the membrane loop to the filler loop ends up replacing elements every few months and blaming the chemistry. A separate warm loop with its own small heater and a high-limit trip costs far less than one set of elements.
Here, often yes. The duty is small, the temperature is low, and the solution is dilute, so the gasket life argument against plate on steam does not apply when the hot side is the plant's hot-water loop. EPDM is comfortable on 1% caustic and on phosphoric or citric acid at 110°F. If steam is the only heat source, a small U-tube with a well-sized control valve is the better match.
Very little. At 30 gpm and a 45°F rise the duty is about 675,000 Btu/h, which condenses roughly 700 lb/h of 15 psig steam. The trap, valve and strainer are sized for that, not for the filler heater next door. A valve sized for a larger heater will hunt and overshoot on this one, which is how a 113°F membrane sees 125°F.
It changes the acid step and the surface allowance. Hard well water leaves carbonate on every warm surface, including the shell side of the heater, so we apply a fouling allowance of 0.001–0.002 and recommend a removable bundle or an openable plate pack. Nitric is rarely needed; phosphoric at 0.5% clears carbonate at 100°F given 15–20 minutes of contact.
On an aseptic filler the CIP loop is part of the sterile boundary. Why that pushes the heater to tri-clamp, 32 Ra and a drainable shell, and what 70 gpm asks of it.
+ Learn More
A filler sanitize is a time-at-temperature test at the coldest valve, not at the heater. Why bottling lines get a once-through heater sized for the full rise.
+ Learn More
Kettles want hot caustic, fermenters knock it cold and CO2 turns it to carbonate. How we size the brewery caustic heater around the cellar instead of the brewhouse.
+ Learn More